Colloid-A-Tron - Technical Specification

Colloid-a-Tron | Technical Specification | Applications | Case Studies

Colloid-A-Tron selection and installation

The COLLOID-A-TRON is installed in the water lines feeding the equipment that has to be protected. It is sized according to the amount of water flowing through that line. For a given size of CAT there is a minimum flow rate above which it will work effectively. You should select the unit whose minimum flow is nearest to the flow rate through the pipe where you want to install the unit.


Example - Selecting appropriate Colloid-A-Tron Sizes

You have a piece of equipment which is prone to scale up, and you want to protect it. The size of the pipe feeding cooling water to the machine is 2 inches diameter and, generally by looking at the pump characteristics, you estimate the water flow to be about 10 m3/hr. With reference to the table below you will see that your flow of 10m3 lies between 7.5 and 12.6 in the m3/hr column. You should therefore select the 40 mm unit (1½ inches) which is suitable for a minimum flow of 7.5 m3/hr. A flow of 10m3 m3/hr is too little for a 2 inch unit, whose required minimum flow is 12.6 m3/hr. The selected COLLOID-A-TRON is installed in the cold water line between the pump and the machine.

Colloid-A-Tron sizes

Nominal
Diameter
Internal Diameter Length Weight Minimum Flow
Inch mm mm Kg m3/hr gals/min
10 3/8 9.25 254 0.34 0.54 1
15 ½ 12.7 254 0.55 1.08 3
20 ¾ 19.05 305 1.04 1.5 7
25 1 25.4 305 1.5 3.3 12
32 31.75 609 3.9 4.8 20
40 38.1 609 4.6 7.5 30
50 2 50.8 609 6.9 12.6 45
65 63.5 913 16.6 19.2 70
80 3 76.2 913 18 27 95
100 4 101.6 913 30 49 170
100(h) 4 101.6 913 34 72 269
125 5 127.0 913 45 90 370
150 6 152.4 913 58 130 550
200 8 203.2 913 98 250 917
250 10 242.0 913 138 400 1468
300 12 304.8 913 227 600 2200
350 14 355.6 913 260 700 2569

 